dc.descriptionThe modeling of a compact fluorescent lamp for harmonic analysis under terminal voltage variation is presented in this paper. The compact fluorescent lamp is represented with the diode bridge rectifier model, which is commonly used for harmonic analysis. The set of parameters is estimated for different values of the terminal voltage applied to the lamp. The equations to estimate the parameters and the required measurements to calculate them are presented. To characterize the lamp an experiment is carried out varying the RMS terminal voltage from 10 V to 131.6 V and for each terminal voltage value the apparent, real and reactive powers, the power factor, the current and the applied voltage are registered. To validate the model in the range of the terminal voltage, the total harmonic distortion of current calculated with the experimental signal and the total harmonic distortion of current calculated with simulation software are compared. The results show that the compact fluorescent lamp can be represented for one set of parameters in the operation range of the terminal voltage suggested by the manufacture.en-US
dc.descriptionEl modelado de una lámpara fluorescente compacta para análisis armónico bajo la variación del voltaje en terminales es presentado en este artículo. La lámpara fluorescente compacta es representada con el modelo de un rectificador tipo puente de diodos, el cual es comúnmente usado para análisis armónico. El conjunto de parámetros es estimado para diferentes valores del voltaje en terminales aplicado a la lámpara. Las ecuaciones para estimar los parámetros y las medidas requeridas para calcularlos son presentadas. Para caracterizar la lámpara un experimento es llevado a cabo variando el voltaje en terminales RMS desde 10 V hasta 131.6 V y para cada valor del voltaje en terminales las potencias aparente, real y reactiva, el factor de potencia, la corriente y el voltaje aplicado son registrados. Para validar el modelo en el rango del voltaje en terminales, la distorsión armónica total de corriente calculada con la señal experimental y la distorsión armónica total de corriente calculada con un software de simulación son comparadas. Los resultados muestran que la lámpara fluorescente compacta puede ser representada por un conjunto de parámetros en el rango de operación del voltaje en terminales sugerido por el fabricante.es-ES
dc.formatapplication/pdf
dc.formattext/html
dc.formattext/xml
dc.languageeng
dc.publisherInstituto Tecnológico Metropolitano (ITM)en-US
dc.relationhttps://revistas.itm.edu.co/index.php/tecnologicas/article/view/780/734
dc.relationhttps://revistas.itm.edu.co/index.php/tecnologicas/article/view/780/981
dc.relationhttps://revistas.itm.edu.co/index.php/tecnologicas/article/view/780/1202
dc.relationhttps://revistas.itm.edu.co/index.php/tecnologicas/article/view/780/1249
dc.relation/*ref*/J. Drapela, R. Langella, J. Slezingr, and A. Testa, “Generalized lamp model for light flicker studies,” Electr. Power Syst. Res., vol. 154, pp. 413–422, Jan. 2018. [2] A. C. Henao-Munoz and A. J. Saavedra-Montes, “Comparison of two mathematical models for nonlinear residential loads,” in 2016 17th International Conference on Harmonics and Quality of Power (ICHQP), 2016, pp. 1–6. [3] J. Cunill-Sola and M. Salichs, “Study and Characterization of Waveforms From Low-Watt (< 25 W) Compact Fluorescent Lamps With Electronic Ballasts,” IEEE Trans. Power Deliv., vol. 22, no. 4, pp. 2305–2311, Oct. 2007. [4] C. Jiang, D. Salles, W. Xu, and W. Freitas, “Assessing the Collective Harmonic Impact of Modern Residential Loads—Part II: Applications,” IEEE Trans. Power Deliv., vol. 27, no. 4, pp. 1947–1955, Oct. 2012. [5] N. R. Watson, T. L. Scott, and S. Hirsch, “Implications for Distribution Networks of High Penetration of Compact Fluorescent Lamps,” IEEE Trans. Power Deliv., vol. 24, no. 3, pp. 1521–1528, Jul. 2009. [6] Z. Radakovic, F. V Topalis, and M. Kostic, “The voltage distortion in low-voltage networks caused by compact fluorescent lamps with electronic gear,” Electr. Power Syst. Res., vol. 73, no. 2, pp. 129–136, Feb. 2005. [7] S. M. Shyni, M. W. Abitha, and C. Bhuvaneswari, “Power factor improvement of compact fluorescent lightings with valley-fill circuit,” in 2017 International Conference on Computation of Power, Energy Information and Commuincation (ICCPEIC), 2017, pp. 622–626. [8] Y. Babacan, C. P. Uzunoğlu, S. Cekli, F. Kaçar, and M. Uğur, “Wavelet analysis of a memristor emulated model proposed for compact fluorescent lamp operated systems,” Electr. Power Syst. Res., vol. 160, pp. 56–62, Jul. 2018. [9] J. Molina and L. Sainz, “Compact Fluorescent Lamp Modeling for Large-Scale Harmonic Penetration Studies,” IEEE Trans. Power Deliv., vol. 30, no. 3, pp. 1523–1531, Jun. 2015. [10] J. Molina and L. Sainz, “Model of Electronic Ballast Compact Fluorescent Lamps,” IEEE Trans. Power Deliv., vol. 29, no. 3, pp. 1363–1371, Jun. 2014. [11] J. Yong, L. Chen, A. B. Nassif, and W. Xu, “A Frequency-Domain Harmonic Model for Compact Fluorescent Lamps,” IEEE Trans. Power Deliv., vol. 25, no. 2, pp. 1182–1189, Apr. 2010. [12] A. B. Nassif and Wilsun Xu, “Characterizing the Harmonic Attenuation Effect of Compact Fluorescent Lamps,” IEEE Trans. Power Deliv., vol. 24, no. 3, pp. 1748–1749, Jul. 2009. [13] J. Molina, J. J. Mesas, and L. Sainz, “Parameter estimation procedure for the equivalent circuit model of compact fluorescent lamps,” Electr. Power Syst. Res., vol. 116, pp. 128–135, Nov. 2014. [14] L. Sainz, J. Cunill, and J. J. Mesas, “Parameter estimation procedures for compact fluorescent lamps with electronic ballasts,” Electr. Power Syst. Res., vol. 95, pp. 77–84, Feb. 2013. [15] G. Malagon-Carvajal, C. Duarte, G. Ordonez-Plata, C. F. M. Almeida, and N. Kagan, “Harmonic attenuation-amplification effect on lighting branch circuits,” in 2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA), 2017, pp. 283–289. [16] F. V. Topalis, I. F. Gonos, and G. A. Vokas, “Arbitrary waveform generator for harmonic distortion tests on compact fluorescent lamps,” Measurement, vol. 30, no. 4, pp. 257–267, Dec. 2001. [17] Mok Yan Kit, W. H. Lau, and C. F. N. Tse, “A study on the effects of voltage distortion on current harmonics generated by modern smps driven home appliances in smart grid network,” in 9th IET International Conference on Advances in Power System Control, Operation and Management (APSCOM 2012), 2012, pp. 85–85. [18] J. Yong, L. Chen, and S. Chen, “Modeling of Home Appliances for Power Distribution System Harmonic Analysis,” IEEE Trans. Power Deliv., vol. 25, no. 4, pp. 3147–3155, Oct. 2010.
dc.rightshttps://creativecommons.org/licenses/by/3.0/deed.es_ESen-US
dc.sourceTecnoLógicas; Vol. 21 No. 42 (2018); 79-94en-US
dc.sourceTecnoLógicas; Vol. 21 Núm. 42 (2018); 79-94es-ES
dc.source2256-5337
dc.source0123-7799
dc.subjectExperimental estimationen-US
dc.subjectnonlinear modelen-US
dc.subjectcompact fluorescent lampsen-US
dc.subjectharmonic studiesen-US
dc.subjectterminal voltage variationen-US
dc.subjectEstimación experimentales-ES
dc.subjectmodelo no-lineales-ES
dc.subjectlámparas fluorescentes compactases-ES
dc.subjectestudios armónicoses-ES
dc.subjectvariación del voltaje en terminaleses-ES
dc.titleExperimental characterization of compact fluorescent lamps for harmonic analysis of power distribution systemsen-US
dc.titleCaracterización experimental de lámparas fluorescentes compactas para el análisis armónico de sistemas de distribución de energía eléctricaes-ES
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typeResearch Papersen-US
dc.typeArtículos de investigaciónes-ES


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem