Mostrar el registro sencillo del ítem

Evaluación de FeCl3 y PAC para la potabilización de agua con alto contenido de color y baja turbiedad

dc.creatorYanza-López, Jeffrey
dc.creatorRivera-Hernández, Robert
dc.creatorGómez-Torres, Luisa
dc.creatorZafra-Mejía, Carlos
dc.date2019-05-15
dc.date.accessioned2021-03-18T21:12:20Z
dc.date.available2021-03-18T21:12:20Z
dc.identifierhttps://revistas.itm.edu.co/index.php/tecnologicas/article/view/1085
dc.identifier10.22430/22565337.1085
dc.identifier.urihttp://test.repositoriodigital.com:8080/handle/123456789/11755
dc.descriptionThe water source for supply from moorland is characterized by its high color and low turbidity, which represents an inconvenience to be considered in most water treatment plants. Internationally, studies have been carried out in this regard, but in general, the proposed solutions are costly and do not fully adapt to this type of Colombian water sources (a country in which no research is recorded). The purpose of this work was the evaluation of FeCl3 as a primary coagulant and PAC (Poly Aluminium Chloride) as auxiliary on a laboratory scale for the water purification with high color and low turbidity. The jar test was performed with FeCl3, PAC, FeCl3 + PAC as a coagulation aid and FeCl3 + PAC as a flocculation aid. The parameters evaluated were pH, color, and turbidity, before and after the treatments; with a dose range for FeCl3 between 36-42 mg/L and for PAC between 0.2-0.5 mg/L. The results displayed that in terms of color removal, the FeCl3 + PAC combination as a coagulation aid showed the highest efficiency among the treatments studied (86.9%), while for turbidity removal the yield reached 80.2%. Likewise, it was demonstrated that this alternative represents a cost savings when compared to PAC as sole coagulant (between 25.5 - 34.2%), depending on the treated flow. Regarding compliance with Colombian regulations in force, the maximum permissible values are (Color = 15 UPC, Turbidity = 2 UNT), with the exception of pH that must be between 6.5-9.0, and that must be stabilized before to send the treated water through the distribution network. en-US
dc.descriptionLa fuente de agua para abastecimiento proveniente del páramo se caracteriza por su alto contenido de color y baja turbiedad, lo que representa un inconveniente por considerar en la mayoría de plantas potabilizadoras. Internacionalmente se han realizado estudios al respecto, pero en general, las soluciones que se plantearon fueron costosas y no se adaptaron totalmente a este tipo de fuentes colombianas (país con escasas investigaciones). El propósito de este trabajo fue la evaluación de FeCl3 como coagulante primario y PAC (Policloruro de aluminio) como auxiliar a escala de laboratorio para la potabilización de agua cruda con elevado color y baja turbiedad. Se realizó el ensayo de jarras con FeCl3, PAC, FeCl3 + PAC como ayudante de coagulación, y FeCl3 + PAC como ayudante de floculación. Los parámetros evaluados fueron pH, color y turbiedad, antes y después de los tratamientos; con un rango de dosis para FeCl3 entre 36-42 mg/L y para PAC entre 0,2-0,5 mg/L. Los resultados revelaron que en términos de eliminación de color la combinación FeCl3 + PAC como ayudante de coagulación presentó la mayor eficiencia entre los tratamientos estudiados (86,9 %), mientras que para remoción de turbiedad el rendimiento alcanzó 80,2 %. De igual manera, se demostró que dicha alternativa representó un ahorro en costos, si se compara con PAC como único coagulante (entre 25,5-34,2 %), dependiendo del caudal tratado. En cuanto al cumplimiento de la normatividad vigente colombiana, se cumplió con los valores máximos permisibles (Color = 15 UPC, Turbiedad = 2 UNT), con excepción del pH que debió estar entre 6,5-9,0, y que debió ser estabilizado antes de enviar el agua tratada por la red de distribución.es-ES
dc.formatapplication/pdf
dc.formattext/xml
dc.formattext/html
dc.languagespa
dc.publisherInstituto Tecnológico Metropolitano (ITM)en-US
dc.relationhttps://revistas.itm.edu.co/index.php/tecnologicas/article/view/1085/1186
dc.relationhttps://revistas.itm.edu.co/index.php/tecnologicas/article/view/1085/1283
dc.relationhttps://revistas.itm.edu.co/index.php/tecnologicas/article/view/1085/1388
dc.relation/*ref*/T. Tuhkanen and A. Ignatev, “Humic and Fulvic Compounds,” in Reference Module in Chemistry, Molecular Sciences and Chemical Engineering, 3rd Editio., Finland: Elsevier, 2005. https://doi.org/10.1016/B978-0-12-409547-2.14413-0, pp. 288–298. [2] M. Sillanpää, “Chapter 1 - General Introduction,” in Natural Organic Matter in Water, Butterworth-Heinemann, Ed. Finland: Butterworth-Heinemann, 2015. https://doi.org/10.1016/B978-0-12-801503-2.00001-X, pp. 1–15. [3] G. A. Edwards and A. Amirtharajah, “Removing Color Caused by Humic Acids,” J. Am. Water Works Assoc., vol. 77, no. 3, pp. 50–57, Mar. 1985. https://doi.org/10.1002/j.1551-8833.1985.tb05508.x. [4] H. R. Mian, G. Hu, K. Hewage, M. J. Rodriguez, and R. Sadiq, “Prioritization of unregulated disinfection by-products in drinking water distribution systems for human health risk mitigation: A critical review,” Water Res., vol. 147, pp. 112–131, Dec. 2018. https://doi.org/10.1016/j.watres.2018.09.054. [5] W. L. Ang, A. W. Mohammad, Y. H. Teow, A. Benamor, and N. Hilal, “Hybrid chitosan/FeCl3 coagulation–membrane processes: Performance evaluation and membrane fouling study in removing natural organic matter,” Sep. Purif. Technol., vol. 152, pp. 23–31, Sep. 2015. https://doi.org/10.1016/j.seppur.2015.07.053. [6] J. Holden, P. J. Chapman, S. M. Palmer, P. Kay, and R. Grayson, “The impacts of prescribed moorland burning on water colour and dissolved organic carbon: A critical synthesis,” J. Environ. Manage., vol. 101, pp. 92–103, Jun. 2012. https://doi.org/10.1016/j.jenvman.2012.02.002. [7] F. Worrall and T. Burt, “Predicting the future DOC flux from upland peat catchments,” J. Hydrol., vol. 300, no. 1–4, pp. 126–139, Jan. 2005. https://doi.org/10.1016/j.jhydrol.2004.06.007. [8] M. C. Collivignarelli, A. Abbà, M. Carnevale Miino, and S. Damiani, “Treatments for color removal from wastewater: State of the art,” J. Environ. Manage., vol. 236, pp. 727–745, Apr. 2019. https://doi.org/10.1016/j.jenvman.2018.11.094. [9] M. Sillanpää, M. C. Ncibi, A. Matilainen, and M. Vepsäläinen, “Removal of natural organic matter in drinking water treatment by coagulation: A comprehensive review,” Chemosphere, vol. 190, pp. 54–71, Jan. 2018. https://doi.org/10.1016/j.chemosphere.2017.09.113. [10] J. Arboleda Valencia, Teoría y práctica de la purificación del agua, Tercera ed. Bogotá: McGraw-Hill Interamericana S.A., 2000. [11] A. Matilainen, M. Vepsäläinen, and M. Sillanpää, “Natural organic matter removal by coagulation during drinking water treatment: A review,” Adv. Colloid Interface Sci., vol. 159, no. 2, pp. 189–197, Sep. 2010. https://doi.org/10.1016/j.cis.2010.06.007. [12] A. M. Sánchez and V. V. Rengifo, “Estudio de los parámetros óptimos de tratabilidad para la fuente de abastecimiento de la planta Palacé en el municipio de Popayán, Departamento del Cauca,” Universidad del Cauca, Popayán, Colombia, 2013. [13] A. P. López-Martínez and J. E. Ramírez-Palencia, “Estudio del comportamiento hidráulico de las unidades de floculación y sedimentación de la planta Palacé en la ciudad de Popayán, mediante el uso de trazadores,” Universidad del Cauca, Popayán, Colombia, 2014. [14] J. Yu, D. Wang, M. Yan, C. Ye, M. Yang, and X. Ge, “Optimized Coagulation of High Alkalinity, Low Temperature and Particle Water: pH Adjustment and Polyelectrolytes as Coagulant Aids,” Environ. Monit. Assess., vol. 131, no. 1–3, pp. 377–386, Jun. 2007. https://doi.org/10.1007/s10661-006-9483-3. [15] R. I. Méndez Novelo, E. R. Castillo Borges, M. R. Sauri Riancho, C. A. Quintal Franco, G. Giácoman Vallejos, and B. Jiménez Cisneros, “Comparación de cuatro tratamientos fisicoquímicos de lixiviados,” Rev. Int. Contam. Ambient., vol. 25, no. 3, pp. 133–145, Aug. 2009. [16] L.-C. Lee et al., “Unusual Roles of Discharge, Slope and SOC in DOC Transport in Small Mountainous Rivers, Taiwan,” Sci. Rep., vol. 9, no. 1, p. 1574, Dec. 2019. https://doi.org/10.1038/s41598-018-38276-x. [17] G. Mitchell and A. T. McDonald, “Catchment Characterization as a Tool for Upland Water Quality Management,” J. Environ. Manage., vol. 44, no. 1, pp. 83–95, May 1995. https://doi.org/10.1006/jema.1995.0032. [18] M. J. Scott, M. N. Jones, C. Woof, and E. Tipping, “Concentrations and fluxes of dissolved organic carbon in drainage water from an upland peat system,” Environ. Int., vol. 24, no. 5–6, pp. 537–546, Jul. 1998. https://doi.org/10.1016/S0160-4120(98)00043-9. [19] A. Baker, L. Bolton, M. Newson, and R. G. M. Spencer, “Spectrophotometric properties of surface water dissolved organic matter in an afforested upland peat catchment,” Hydrol. Process., vol. 22, no. 13, pp. 2325–2336, Jun. 2008. https://doi.org/10.1002/hyp.6827. [20] H. H. Hermann, E. Hoffman, and H. Odegaard, Chemical Water and Wastewater Treatment VIII. Orlando: IWA Publishing, 2004. [21] P. Jarvis, B. Jefferson, and S. A. Parsons, “Breakage, Regrowth, and Fractal Nature of Natural Organic Matter Flocs,” Environ. Sci. Technol., vol. 39, no. 7, pp. 2307–2314, Apr. 2005. https://doi.org/10.1021/es048854x. [22] H. Ratnaweera, “Comparison of the coagulation behavior of different Norwegian aquatic NOM sources,” Environ. Int., vol. 25, no. 2–3, pp. 347–355, Apr. 1999. https://doi.org/10.1016/S0160-4120(98)00112-3. [23] E. Smith and Y. Kamal, “Optimizing treatment for reduction of disinfection by-product (DBP) formation,” Water Sci. Technol. Water Supply, vol. 9, no. 2, pp. 191–198, Jun. 2009. https://doi.org/10.2166/ws.2009.120. [24] J. Tian, Z. Chen, J. Nan, H. Liang, and G. Li, “Integrative membrane coagulation adsorption bioreactor (MCABR) for enhanced organic matter removal in drinking water treatment,” J. Memb. Sci., vol. 352, no. 1–2, pp. 205–212, Apr. 2010. https://doi.org/10.1016/j.memsci.2010.02.018. [25] M. Yan, D. Wang, J. Qu, J. Ni, and C. W. K. Chow, “Enhanced coagulation for high alkalinity and micro-polluted water: The third way through coagulant optimization,” Water Res., vol. 42, no. 8–9, pp. 2278–2286, Apr. 2008. https://doi.org/10.1016/j.watres.2007.12.006. [26] Acueducto y Alcantarillado de Popayán S.A E.S.P., “Manual para la construcción de redes de acueducto y alcantarillado en el municipio de Popayan,” Popayán, Colombia, 2009. [27] Instituto Colombiano de Normas Técnicas, Procedimiento para el ensayo de coagulación-floculación en un recipiente con agua o método de jarras-NTC3903. 2010, p. 9. [28] Ministerio de Vivienda, Ciudad y Territorio de Colombia, “Reglamento Técnico del Sector de Agua Potable y Saneamiento Básico - RAS,” Reglamento Técnico del Sector de Agua Potable y Saneamiento Básico - RAS, 2017. http://www.minvivienda.gov.co/viceministerios/viceministerio-de-agua/reglamento-tecnico-del-sector/reglamento-tecnico-del-sector-de-agua-potable . [29] W. J. Weber, Control de la calidad del agua: procesos fisicoquímicos. Barcelona: Reverte, 1979. [30] D. Trujillo, L. F. Duque, J. S. Arcila, A. Rincón, S. Pacheco, and O. F. Herrera, “Remoción de turbiedad en agua de una fuente natural mediante coagulación/floculación usando almidón de plátano,” Rev. ION, vol. 27, no. 1, pp. 17–34, Jun. 2014. [31] A. E. Childress, E. M. Vrijenhoek, M. Elimelech, T. S. Tanaka, and M. D. Beuhler, “Particulate and THM Precursor Removal with Ferric Chloride,” J. Environ. Eng., vol. 125, no. 11, pp. 1054–1061, Nov. 1999. https://doi.org/10.1061/(ASCE)0733-9372(1999)125:11(1054)) [32] R. Li et al., “Effects of chlorination operating conditions on trihalomethane formation potential in polyaluminum chloride-polymer coagulated effluent,” J. Hazard. Mater., vol. 285, pp. 103–108, Mar. 2015. https://doi.org/10.1016/j.jhazmat.2014.11.048. [33] A. M. Hansen, T. E. C. Kraus, S. M. Bachand, W. R. Horwath, and P. A. M. Bachand, “Wetlands receiving water treated with coagulants improve water quality by removing dissolved organic carbon and disinfection byproduct precursors,” Sci. Total Environ., vol. 622–623, pp. 603–613, May 2018. https://doi.org/10.1016/j.scitotenv.2017.11.205. [34] D. A. Cornwell, D. K. Roth, and R. A. Brown, Minimizing water treatment residual discharges to surface water. Denver: Water Research Foundation, 2010.
dc.rightsCopyright (c) 2019 TecnoLógicasen-US
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/4.0en-US
dc.sourceTecnoLógicas; Vol. 22 No. 45 (2019); 9-21en-US
dc.sourceTecnoLógicas; Vol. 22 Núm. 45 (2019); 9-21es-ES
dc.source2256-5337
dc.source0123-7799
dc.subjectFerric chloride (FeCl3)en-US
dc.subjectAluminum polychloride (PAC)en-US
dc.subjectHumic substances (SH)en-US
dc.subjectColoren-US
dc.subjectTurbidityen-US
dc.subjectCloruro férrico (FeCl3)es-ES
dc.subjectPolicloruro de aluminio (PAC)es-ES
dc.subjectSustancias húmicas (SH)es-ES
dc.subjectColores-ES
dc.subjectTurbiedades-ES
dc.titleEvaluation of FeCl3 and PAC for the potabilization of water with high content of color and low turbidityen-US
dc.titleEvaluación de FeCl3 y PAC para la potabilización de agua con alto contenido de color y baja turbiedades-ES
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typeResearch Papersen-US
dc.typeArtículos de investigaciónes-ES


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem