SaO2/FiO2 Tomada por Pulso-oximetría, herramienta para predecir requerimiento de ventilación mecánica en pacientes con Neumonía Adquirida en la comunidad
SaO2 / FiO2 Taken by Pulse-oximetry, tool to predict requirement for mechanical ventilation in patients with Community acquired pneumonia Community acquired
| dc.contributor | Bastidas Goyes, Alirio Rodrigo | |
| dc.creator | Jaimes Duque, David Enrique | |
| dc.creator | Rengifo Peláez, Luz Esneda | |
| dc.date | 2015-03-05T14:29:21Z | |
| dc.date | 2015-07-13T19:36:03Z | |
| dc.date | 2019-12-30T19:03:38Z | |
| dc.date | 2015-03-05T14:29:21Z | |
| dc.date | 2015-07-13T19:36:03Z | |
| dc.date | 2019-12-30T19:03:38Z | |
| dc.date | 2014-09-27 | |
| dc.date.accessioned | 2026-03-25T19:26:29Z | |
| dc.date.available | 2026-03-25T19:26:29Z | |
| dc.identifier | https://hdl.handle.net/10654/12625 | |
| dc.identifier.uri | http://test.repositoriodigital.com:8080/handle/123456789/201048 | |
| dc.description | Resumen: La relación SaO2FiO2 tomada por pulso-oximetria ha sido comparada con la relación PaO2/FiO2, y validada en varios estudios como predictor temprano de desarrollo de SDRA, así como establecido parámetros de dicha relación que la permitan utilizar en el cálculo de la escala SOFA en su componente respiratorio, y como parámetro ventilatorio en el proceso de liberación de ventilación mecánica, por esta razón surge la idea de estudiarlo como predictor de requerimiento de ventilación mecánica en pacientes con diagnóstico de neumonía adquirida en la comunidad. | |
| dc.description | The relationship SaO2FiO2 pulse-oximetry taken has been compared with PaO 2 / FiO 2, and validated in several studies as a predictor early development of ARDS and set parameters that allow this relationship in the calculation the SOFA scale in their respiratory component, and as ventilatory parameter in the process of releasing mechanical ventilation, therefore arises the idea of studying as a predictor of requirement for mechanical ventilation in patients diagnosed with acquired pneumonia in the community. | |
| dc.description | NO | |
| dc.format | ||
| dc.format | ||
| dc.format | application/octet-stream | |
| dc.language | spa | |
| dc.publisher | Universidad Militar Nueva Granada | |
| dc.publisher | Medicina interna | |
| dc.publisher | Facultad de Medicina | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | ventilación mecánica | |
| dc.subject | oxigenación | |
| dc.subject | especificidad | |
| dc.subject | sensibilidad | |
| dc.subject | MEDICINA INTERNA | |
| dc.subject | VENTILACION MECANICA | |
| dc.subject | ENFERMEDADES RESPIRATORIAS | |
| dc.subject | NEUMONIA | |
| dc.subject | Neumonía adquirida en la comunidad | |
| dc.subject | Community-acquired pneumonia | |
| dc.subject | mechanical ventilation | |
| dc.subject | oxygenation | |
| dc.subject | sensitivity and specificity | |
| dc.title | SaO2/FiO2 Tomada por Pulso-oximetría, herramienta para predecir requerimiento de ventilación mecánica en pacientes con Neumonía Adquirida en la comunidad | |
| dc.title | SaO2 / FiO2 Taken by Pulse-oximetry, tool to predict requirement for mechanical ventilation in patients with Community acquired pneumonia Community acquired | |
| dc.type | info:eu-repo/semantics/bachelorThesis | |
| dc.type | Trabajo de grado |
Ficheros en el ítem
| Ficheros | Tamaño | Formato | Ver |
|---|---|---|---|
|
No hay ficheros asociados a este ítem. |
|||
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Revisión RedCol 2 [1742]