Mostrar el registro sencillo del ítem

Impact Analysis of the Distributed Generation in an IEEE 37 Node System Using DigSilent, ATP and Matlab

dc.contributorSantamaría Piedrahita, Francisco
dc.creatorBobadilla Restrepo, Diego Felipe
dc.creatorVelandia Piraquive, Anderson Jair
dc.date2018-01-25T21:18:57Z
dc.date2018-01-25T21:18:57Z
dc.date2017-11-21
dc.date.accessioned2025-04-29T21:36:49Z
dc.date.available2025-04-29T21:36:49Z
dc.identifierhttp://hdl.handle.net/11349/7379
dc.identifier.urihttp://test.repositoriodigital.com:8080/handle/123456789/94591
dc.descriptionEste estudio tiene tres partes fundamentales, en la primera se trabajó toda la fundamentación teórica necesaria para la implementación del sistema de distribución base a trabajar y el modelamiento de las fuentes de generación distribuida. En la segunda parte se dan a conocer en primera instancia los resultados de los perfiles de tensión en estado estable, las sobretensiones, sobrecorrientes, tiempos de ocurrencia y de asentamiento en estado transitorio; y los perfiles de tensión y las corrientes de cortocircuito en estado de falla del sistema de distribución sin GD. En la última parte, se muestran los resultados para los mismos tres estados mencionados, pero ahora con la inclusión de las tres unidades de GD y con tres niveles distintos de penetración (100, 200 y 500 kW por cada unidad de GD). Finalmente se analizó el comportamiento de cada software frente a los diferentes escenarios bajo estudio, determinando las diferencias entre simuladores y estableciendo los motivos de las mismas. Por último, se contrastaron las ventajas y limitaciones de cada uno para evaluar sus capacidades frente a los distintos casos de estudio.
dc.descriptionThis study has three fundamental parts, in the first one we worked on all the theoretical foundation necessary for the implementation of the base distribution system to work and the modeling of the sources of distributed generation. In the second part, the results of the stable state voltage profiles, overvoltages, overcurrents, times of occurrence and settlement in the transitory state are presented in the first instance; and the voltage profiles and short-circuit currents in the fault state of the distribution system without GD. In the last part, the results are shown for the same three mentioned states, but now with the inclusion of the three GD units and with three different levels of penetration (100, 200 and 500 kW for each GD unit). Finally, the behavior of each software was analyzed against the different scenarios under study, determining the differences between simulators and establishing the reasons for them. Finally, the advantages and limitations of each one were contrasted in order to evaluate their capacities in relation to the different study cases.
dc.formatpdf
dc.formatapplication/pdf
dc.languagespa
dc.rightsAtribución-NoComercial-SinDerivadas 4.0 Internacional
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAbierto (Texto Completo)
dc.subjectGeneración Distribuida
dc.subjectTransitorio
dc.subjectFalla
dc.subjectFlujos de Carga
dc.subjectINGENIERÍA ELÉCTRICA - TESIS Y DISERTACIONES ACADÉMICAS
dc.subjectGENERACIÓN DE ENERGÍA
dc.subjectSISTEMAS DE ENERGÍA FOTOVOLTAICA
dc.subjectDISTRIBUCIÓN DE ENERGÍA ELÉCTRICA
dc.subjectDistributed Generation
dc.subjectTransient
dc.subjectFault
dc.subjectLoad Flow
dc.titleAnálisis del Impacto de la Generación Distribuida en un Sistema IEEE de 37 Nodos Usando DigSilent, ATP y Matlab
dc.titleImpact Analysis of the Distributed Generation in an IEEE 37 Node System Using DigSilent, ATP and Matlab
dc.typeCreación o Interpretación
dc.typeinfo:eu-repo/semantics/bachelorThesis
dc.typehttp://purl.org/coar/resource_type/c_7a1f


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem